Skip to main content

Table 3 Comparison between 3D TEE semi-automatic MA area and MA area derived from 2D TTE MA diameters

From: Two-dimensional transthoracic measure of mitral annulus in mitral valve prolapse and moderate to severe regurgitation: a method comparison analysis with three-dimensional transesophageal echocardiography

MA area derived from 2D TTE MA diameters

Mean difference between methods ± SD or median difference (25th–75th percentiles), (mm2)

% of systematic underestimation

Precision (mm2)

Percent error (%)

Method 1, MA area (mm2) (circular model, A4c)

79 ± 289

6

1,132

82

Method 2, MA area, (mm2) (elliptical model, A2c-A4c)

108 (− 51 to + 370)

8

912

66

Method 3, MA area, (mm2) (elliptical model, A2c-PLAX)

350 ± 265

25

1,040

75

  1. A4c apical 4 chamber, A3c apical 3 chamber, A2c apical 2 chamber, MA mitral annulus, PLAX parasternal long-axis, SD standard deviations, 3D TEE 3-dimensional transesophageal echocardiography, 2D TTE 2-dimensional transesophageal echocardiography