Enhancing cardiology imaging: usability and implications of aortic annulus sizing software in transcatheter aortic valve replacement planning

In cardiovascular imaging, supporting imaging software is pivotal in enhancing the accuracy, efficiency, and overall quality of diagnostic and interventional procedures. These software applications serve as indispensable tools for radiologists, cardiologists, and other healthcare professionals in the field as they can enhance the visualization and analysis of complex cardiovascular structures in high detail, support quantitative assessment, and enable post-processing tasks like image filtering, noise removal, and contrast enhancement, all of which contribute to clearer images [1, 2].

In the current issue of the Journal of Cardiovascular Imaging, Spanke et al. [3] conducted a comparative study on the usability and accuracy of two different aortic annulus sizing software programs, namely “3mensio Structural Heart (PIE Medical Imaging)” and “Valve ASSIST 2 (GE Healthcare),” for patients undergoing transcatheter aortic valve replacement (TAVR). This study is a significant contribution to the field of cardiology imaging, focusing on the critical aspect of preprocedural sizing in TAVR, which directly impacts patient outcomes. Despite the limited number of participants (11 for beginners in each imaging software group and nine for experts in the true reference group), the study’s methodology involved a randomized controlled design with both program-inexperienced users and experts, providing a comprehensive evaluation. The study demonstrated that Valve ASSIST 2 outperforms Structural Heart in terms of usability, with higher scores, faster measurements, and fewer questions needed. The detailed reporting on the percentage of correct valve size selections for both programs provides valuable insights into the real-world implications of usability on clinical decision-making. The authors also emphasize the need for further research involving experienced TAVR specialists, which is a logical next step to understanding the broader implications of software usability in the field.

Various aspects can evaluate imaging supporting software, such as usability, accuracy, speed, and efficiency, as demonstrated in the current study using tools like the System Usability Scale (SUS), ISONORM 9241/110-S questionnaire, the number of questions needed for measurements, and time on task. However, there are limitations in considering the average of experts’ measurement as an absolute true value. This suggests the necessity for standardized criteria to evaluate the numerous imaging software that has already been developed and will continue to be developed in the future [4, 5].

The future of cardiovascular imaging software is likely to be closely linked with artificial intelligence (AI). Machine learning algorithms can aid in automated disease detection, image analysis, and risk stratification. AI may assist in flagging anomalies in real time, thus expediting diagnosis and treatment and making it particularly suitable for handling the ever-growing volume of medical images in healthcare systems [6, 7].

In summary, this research contributes valuable insights into the usability of aortic annulus sizing software programs for TAVR planning. The well-structured study design and clear presentation of results make it a noteworthy addition to the field of cardiology imaging and hold promise for improving the precision of TAVR procedures.

Availability of data and materials

Not applicable.

Abbreviations

AI:

Artificial intelligence

TAVR:

Transcatheter aortic valve replacement

References

  1. Jilaihawi H, Doctor N, Kashif M, Chakravarty T, Rafique A, Makar M, et al. Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol. 2013;61:908–16.

    Article  PubMed  Google Scholar 

  2. Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A, et al. Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging. 2013;6:249–62.

    Article  PubMed  Google Scholar 

  3. Spanke J, Nübel J, Hölschermann F, Tambor G. Usability and accuracy of two different aortic annulus sizing software programs in patients undergoing transcatheter aortic valve replacement. J Cardiovasc Imaging. 2024;32:1.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Knobloch G, Sweetman S, Bartels C, Raval A, Gimelli G, Jacobson K, et al. Inter- and intra-observer repeatability of aortic annulus measurements on screening CT for transcatheter aortic valve replacement (TAVR): implications for appropriate device sizing. Eur J Radiol. 2018;105:209–15.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Spitzer E, Camacho B, Mrevlje B, Brandendburg HJ, Ren CB. Echocardiography core laboratory validation of a novel vendor-independent web-based software for the assessment of left ventricular global longitudinal strain. J Cardiovasc Imaging. 2023;31:135–41.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Evertz R, Lange T, Backhaus SJ, Schulz A, Beuthner BE, Topci R, et al. Artificial intelligence enabled fully automated CMR function quantification for optimized risk stratification in patients undergoing transcatheter aortic valve replacement. J Interv Cardiol. 2022;2022:1368878.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Olaisen S, Smistad E, Espeland T, Hu J, Pasdeloup D, Østvik A, et al. Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence: clinical validation in real time and large databases. Eur Heart J Cardiovasc Imaging. 2024;25:383–95.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jah Yeon Choi.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

Not applicable.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Choi, J.Y. Enhancing cardiology imaging: usability and implications of aortic annulus sizing software in transcatheter aortic valve replacement planning. J Cardiovasc Imaging 32, 20 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s44348-024-00016-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s44348-024-00016-3